TGuide S96 Kaihoko Aunoa Nucleic Acid

Tino teitei puta noa, me nga tauira 192 ka tangohia i te waa kotahi.

Ko te TGuide S96 Aunoa Motuhake Nucleic Acid Tango e tango ana i te hou o te tokotoko aukume me te whakawhiti i nga tikanga peara aukume. Ko nga pereti puna hohonu 96-hohonu me nga momo rerekee tangohanga tangihanga peariki autetehi ka whakamahia hei tango aunoa me te pure i te waikawa ngota mai i te 1-192 toto / kiri / kiko / wheori me etahi atu tauira.

Ka taea te whakakii i tenei tangohanga ki te waahanga 24 e taea ai te urutau ki nga tauira rahi-rahi. He mea rite ki nga TIANGEN reagents kua kiki-mua, ka taea te tango i nga tauira 1-24. Ko te rahinga tauira nui e whakahaerehia ana e te taputapu 5 ml. He pai rawa atu mo te tangohanga o te waikawa nucleic koreutu i te serum me te plasma. He nui te hua o te tangohanga me te ma pono, ka taea te whakamahi i nga mara penei i te kitenga puku, NIPT, etc.

Ngeru. No. Rahinga Peke
OSE-S96-01 1 Whakatakotoria
OSE-S96-02 1 Whakatakotoranga
OSE-S96-03 1 Whakatakotoranga

Taipitopito Hua

Tohu Hua

Tawhā Whakahaere

Operating Parameters

Tumuaki

Principle

Nga Taurangi maha mo te Hua Nui Rawa me te Tino Ma

Aratau adsorption porohita, kakama te whakahoki i te peara autō ≥ 98%
Na roto i te aratau adsorption tohanga me te tere whakatikatika, ka pania nga peara aukume ki te pito o te tokotoko aukume i te wa e heke haere ana te heke o te tokotoko aukume, kia pai ai te hipoki o te hiko, ka taea tonu e te eluent te taupoki i nga aukume katoa. pirepire ka porohita mo nga wa maha, a tae noa ki nga peara aukume me te rahi o te korakora iti ka taea te whakakorikori.

Operating Parameters  Operating Parameters   Principle Principle  Multiple Guarantees of Ultra High Yield & Purity  Circulation adsorption mode, magnetic bead recovery efficiency ≥ 98% Through the circulation adsorption mode with adjustable speed, magnetic beads are adsorbed on the tip of the magnetic rod during the slow descending process of the magnetic rod, so that under the condition that the elution volume is small, the eluent can still cover all the magnetic beads and circulate for many times, and even the magnetic beads with small particle sizes can be effectively adsorbed.       Four-Dimensional Integrated Motion Mode Ensures The Best Blending Effect ■ The four-dimensional integrated motion mode of X/Y/Z motion of the mechanical arm integral module and vibration of the mixing parts ensures stable operation and high precision of the instrument; ■ The instrument has high oscillation frequency and adjustable multi-gear, which is suitable for different reagent integration schemes; ■ The vibration amplitude can be adaptively adjusted according to the solution volume set by the user, thus achieving the best experimental mixing effect. Professional Pollution Control & Safety Guarantee ■ UV sterilization module: It can ensure that the operation in the machine reaches a sterile environment; ■ Anti-aerosol fan: Keep the air in the instrument in circulation to avoid aerosol pollution; ■ Anti-dripping disc: Effectively avoid cross contamination between wells and plates; ■ Closed operation: If the door is opened accidentally, the instrument will automatically pause to ensure safety; ■ Disposable reagent consumables: To protect the safety of laboratory personnel and laboratory environment to the greatest extent. Reasonable Design of The Expandable Throughout The matrix arrangement of double row and four plate positions not only ensures the expandability of the experiment, but also reduces the occupied area of the instrument and effectively uses the space. Under limited conditions, it can be expanded to extract 192 samples at a time, ensuring a ultra-high throughput extraction capability. With double heating modules of lysis/elution, the extraction efficiency can be improved.        Intuitive and User-Friendly Human-Computer Interaction Interface The 10.1-inch touch computer is equipped with Windows system and touch operation, which is simple and easy to use, conforming to the user’s usage habits. The program setting takes full account of the experimental expansibility, multi-parameter free configuration, and large integration and development space. Product Guide for TGuide S96  Features ■ Extremely high throughout: 192 samples can be extracted in a single run. ■ Operation mode: 10.1-inch touch interface (Windows system) ■ Magnetic bead adsorption: Cycle adsorption, recovery efficiency ≥ 98% ■ Movement mode: Four-dimensional integrated movement, confirming the best mixing effect ■ Replaceable modules: A 24-flux modules can be provided, with flexible processing volume ■ Professional contamination prevention: Effective avoidance of cross-contamination between wells and plates

Ko te Aratau Miihini Whakahoahoa Tuawha e wha te whakarite i te painga whakaranu pai

■ Ko te aratau nekehanga whakauru e wha-waahanga o te nekehanga X / Y / Z o te miihini whakauru waahanga whakauru me te wiri o nga waahanga whakaranu ka whakarite i te mahi pumau me te tino tika o te taputapu.
■ Ko te taputapu he maha nga rererangi whakahekeheke me te taputapu-maha e taea ana te whakarite, e tika ana mo nga kaupapa whakauru whakauru rerekee;
■ Ka taea te whakarereke i te kaha o te wiri i runga i te rahinga otinga i whakatauhia e te kaiwhakamahi, na reira ka tutuki te painga o te whakaranu whakamatau.
Whakahaere Pollution Ngaio & Tohu Haumaru
■ UV sterilization module: Ka taea e ia te whakarite kia tae atu te mahi i roto i te miihini ki tetahi taiao horomata;
■ Peera anti-aerosol: Purihia te hau ki roto i te taputapu kia rere kia kore e poke te aerosol;
■ Kopae anti-turuturu: Kaweahia te karo i te parekura i waenga i nga puna me nga pereti;
■ Mahi kati: Mena ka whakatuwheratia te kuaha, ka okioki aunoa te taputapu ki te whakarite kia ahuru;
■ Ka taea te whakamahi reagent reagent: Hei tiaki i te ahuru o nga kaimahi taiwhanga me te taiao taiwhanga kia nui rawa atu.
Hoahoa whaitake o Te Roha Katoa
Ko te whakariterite i te kopu o te haupae taarua me nga tuunga pereti e wha, ehara i te mea ko te whaanui o te whakamatau anake, engari ko te whakaiti i te waahanga o te taputapu me te whakamahi tika i te waahi. I raro i nga tikanga iti, ka taea te whakawhaanui ki te tango 192 tauira i te wa kotahi, kia whakarite i te kaha o te tangohanga whakaputa-teitei. Ma nga waahanga whakawera rua o te lysis / hihiko, ka taea te whakapai ake i te tangohanga tangohanga.

Operating Parameters  Operating Parameters   Principle Principle  Multiple Guarantees of Ultra High Yield & Purity  Circulation adsorption mode, magnetic bead recovery efficiency ≥ 98% Through the circulation adsorption mode with adjustable speed, magnetic beads are adsorbed on the tip of the magnetic rod during the slow descending process of the magnetic rod, so that under the condition that the elution volume is small, the eluent can still cover all the magnetic beads and circulate for many times, and even the magnetic beads with small particle sizes can be effectively adsorbed.       Four-Dimensional Integrated Motion Mode Ensures The Best Blending Effect ■ The four-dimensional integrated motion mode of X/Y/Z motion of the mechanical arm integral module and vibration of the mixing parts ensures stable operation and high precision of the instrument; ■ The instrument has high oscillation frequency and adjustable multi-gear, which is suitable for different reagent integration schemes; ■ The vibration amplitude can be adaptively adjusted according to the solution volume set by the user, thus achieving the best experimental mixing effect. Professional Pollution Control & Safety Guarantee ■ UV sterilization module: It can ensure that the operation in the machine reaches a sterile environment; ■ Anti-aerosol fan: Keep the air in the instrument in circulation to avoid aerosol pollution; ■ Anti-dripping disc: Effectively avoid cross contamination between wells and plates; ■ Closed operation: If the door is opened accidentally, the instrument will automatically pause to ensure safety; ■ Disposable reagent consumables: To protect the safety of laboratory personnel and laboratory environment to the greatest extent. Reasonable Design of The Expandable Throughout The matrix arrangement of double row and four plate positions not only ensures the expandability of the experiment, but also reduces the occupied area of the instrument and effectively uses the space. Under limited conditions, it can be expanded to extract 192 samples at a time, ensuring a ultra-high throughput extraction capability. With double heating modules of lysis/elution, the extraction efficiency can be improved.        Intuitive and User-Friendly Human-Computer Interaction Interface The 10.1-inch touch computer is equipped with Windows system and touch operation, which is simple and easy to use, conforming to the user’s usage habits. The program setting takes full account of the experimental expansibility, multi-parameter free configuration, and large integration and development space. Product Guide for TGuide S96  Features ■ Extremely high throughout: 192 samples can be extracted in a single run. ■ Operation mode: 10.1-inch touch interface (Windows system) ■ Magnetic bead adsorption: Cycle adsorption, recovery efficiency ≥ 98% ■ Movement mode: Four-dimensional integrated movement, confirming the best mixing effect ■ Replaceable modules: A 24-flux modules can be provided, with flexible processing volume ■ Professional contamination prevention: Effective avoidance of cross-contamination between wells and plates

Atanga Ngahau me te Kaiwhakamahi-Whakahoahoa Atanga Whakawhanaunga Tangata-Rorohiko
Ko te rorohiko pa 10.1-inihi he rite ki te punaha Windows me te mahi pa, he ngawari noa iho he ngawari ki te whakamahi, e haangai ana ki nga tikanga whakamahi a te kaiwhakamahi. Ko te whakaturanga o te papatono e whakaatu ana i te whaanuitanga o te whakamatau, te whirihoranga-koreutu mo te waahanga-maha, me te whakauru nui me te waahi whanaketanga.

Aratohu Hua mo te TGuide S96

Operating Parameters  Operating Parameters   Principle Principle  Multiple Guarantees of Ultra High Yield & Purity  Circulation adsorption mode, magnetic bead recovery efficiency ≥ 98% Through the circulation adsorption mode with adjustable speed, magnetic beads are adsorbed on the tip of the magnetic rod during the slow descending process of the magnetic rod, so that under the condition that the elution volume is small, the eluent can still cover all the magnetic beads and circulate for many times, and even the magnetic beads with small particle sizes can be effectively adsorbed.       Four-Dimensional Integrated Motion Mode Ensures The Best Blending Effect ■ The four-dimensional integrated motion mode of X/Y/Z motion of the mechanical arm integral module and vibration of the mixing parts ensures stable operation and high precision of the instrument; ■ The instrument has high oscillation frequency and adjustable multi-gear, which is suitable for different reagent integration schemes; ■ The vibration amplitude can be adaptively adjusted according to the solution volume set by the user, thus achieving the best experimental mixing effect. Professional Pollution Control & Safety Guarantee ■ UV sterilization module: It can ensure that the operation in the machine reaches a sterile environment; ■ Anti-aerosol fan: Keep the air in the instrument in circulation to avoid aerosol pollution; ■ Anti-dripping disc: Effectively avoid cross contamination between wells and plates; ■ Closed operation: If the door is opened accidentally, the instrument will automatically pause to ensure safety; ■ Disposable reagent consumables: To protect the safety of laboratory personnel and laboratory environment to the greatest extent. Reasonable Design of The Expandable Throughout The matrix arrangement of double row and four plate positions not only ensures the expandability of the experiment, but also reduces the occupied area of the instrument and effectively uses the space. Under limited conditions, it can be expanded to extract 192 samples at a time, ensuring a ultra-high throughput extraction capability. With double heating modules of lysis/elution, the extraction efficiency can be improved.        Intuitive and User-Friendly Human-Computer Interaction Interface The 10.1-inch touch computer is equipped with Windows system and touch operation, which is simple and easy to use, conforming to the user’s usage habits. The program setting takes full account of the experimental expansibility, multi-parameter free configuration, and large integration and development space. Product Guide for TGuide S96  Features ■ Extremely high throughout: 192 samples can be extracted in a single run. ■ Operation mode: 10.1-inch touch interface (Windows system) ■ Magnetic bead adsorption: Cycle adsorption, recovery efficiency ≥ 98% ■ Movement mode: Four-dimensional integrated movement, confirming the best mixing effect ■ Replaceable modules: A 24-flux modules can be provided, with flexible processing volume ■ Professional contamination prevention: Effective avoidance of cross-contamination between wells and plates

Āhuahira

■ Tino teitei puta noa: Ka taea te tango i nga tauira 192 i te oma kotahi.
■ Mahinga whakahaere: 10.1-inihi atanga pa (punaha Windows)
■ Te whakatairanga i te peera aukume: Huringa panui, whakaora pai ≥ 98%
■ Mahinga nekehanga: E wha-waahanga te nekehanga whakauru, e whakau ana i te painga whakaranu pai
■ Nga waahanga ka taea te whakakapi: Ka taea te whakarato i nga waahanga 24-rerewai, me te rahinga tukatuka ngawari
■ Te aukati i te whakapoke i te ngaiotanga: Te karo tino i te paru-paru i waenga i nga puna me nga pereti

Ka taea te whakarite i nga hua katoa mo te ODM / OEM. Mo nga taipitopito,pāwhiritia koa Ratonga Whakaritea (ODM / OEM)


  • Tōmua:
  • Panuku:

  • product_certificate04 product_certificate01 product_certificate03 product_certificate02
    ×
  • Tuhia to korero ki konei ka tuku mai ki a maatau

    Nga waahanga hua